Aaron® 2250™ Generator/Desiccator Unit
The Aaron 2250 is a multipurpose electrosurgical generator for use in the modern operating room and surgi-center. It features both monopolar and bipolar functions to satisfy all of your surgical demands with safety, flexibility, reliability, and convenience. Ten Blend Settings You do not have to settle . . . More details
Product Details
The Aaron 2250 is a multipurpose electrosurgical generator for use in the modern operating room and surgi-center. It features both monopolar and bipolar functions to satisfy all of your surgical demands with safety, flexibility, reliability, and convenience.
Ten Blend Settings
You do not have to settle for one or two blend modes anymore. With the Aaron 2250 you have ten different blend settings plus cut, all with 200 watts maximum power output for the most demanding procedures
Two Levels of Coagulation
It also has two levels of coagulation: Coagulation (120 watts maximum power) and Fulguration (80 watts maximum power), plus Bipolar (80 watts maximum power).
Digital Power Control
In addition, the Aaron 2250 delivers consistent, repeatable power into varying load impedances, with BovieFDFS™ (Fast Digital Feedback System), thereby greatly reducing the need for changing the power setting to obtain the desired surgical effect.
Designed for Safety
Electrosurgical safety is a combination of good equipment design and safe surgical practices. The Aaron 2250, as part of this combination, represents state-of-the-art design using the latest digital components.
Bovie incorporated automatic safety systems into the Aaron 2250 like self-test circuits, audible tones, discreet outputs, and isolated output circuitry.
BovieNEM™ means safety is digitally designed inside. The FCFS™ (first come first served) discrete output design of the Aaron 2250 enhances safety by allowing only one output to be activated at any given time. This feature assures that only the device you first activate will be an active device. Secondary commands will not override the first command.
As an example: while the monopolar foot controlled output is activated, all handswitching is inactive, as well as the bipolar footswitch capability. For additional safety, this unit has totally separate bipolar controls, discrete output, dispersive electrode fault alarms in both sensing and non-sensing modes, and is designed with an isolated RF output.
Digital Error Detection
Digital error detection means unsurpassed safety for the surgeon, O.R. staff, and patient.
The Aaron 2250 constantly monitors every aspect of the Aaron 2250's output. At the sign of any problem the machine instantly disables the output and displays the appropriate error code on the display.
Dimensions and Weight
Width: 31.1 cm (12.3")
Height: 15.3 cm (6.0")
Depth: 41.3 cm (16.3")
Weight: < 8.8 kg (< 19 lbs.)
Warranty
(Unit) - 2 years
Ships With:
Unit, Power Cord and User's guide.
Special order item, therefore it cannot be canceled once the order has been placed and is non-returnable after it has been received.
Ten Blend Settings
You do not have to settle for one or two blend modes anymore. With the Aaron 2250 you have ten different blend settings plus cut, all with 200 watts maximum power output for the most demanding procedures
Two Levels of Coagulation
It also has two levels of coagulation: Coagulation (120 watts maximum power) and Fulguration (80 watts maximum power), plus Bipolar (80 watts maximum power).
Digital Power Control
In addition, the Aaron 2250 delivers consistent, repeatable power into varying load impedances, with BovieFDFS™ (Fast Digital Feedback System), thereby greatly reducing the need for changing the power setting to obtain the desired surgical effect.
Designed for Safety
Electrosurgical safety is a combination of good equipment design and safe surgical practices. The Aaron 2250, as part of this combination, represents state-of-the-art design using the latest digital components.
Bovie incorporated automatic safety systems into the Aaron 2250 like self-test circuits, audible tones, discreet outputs, and isolated output circuitry.
BovieNEM™ means safety is digitally designed inside. The FCFS™ (first come first served) discrete output design of the Aaron 2250 enhances safety by allowing only one output to be activated at any given time. This feature assures that only the device you first activate will be an active device. Secondary commands will not override the first command.
As an example: while the monopolar foot controlled output is activated, all handswitching is inactive, as well as the bipolar footswitch capability. For additional safety, this unit has totally separate bipolar controls, discrete output, dispersive electrode fault alarms in both sensing and non-sensing modes, and is designed with an isolated RF output.
Digital Error Detection
Digital error detection means unsurpassed safety for the surgeon, O.R. staff, and patient.
The Aaron 2250 constantly monitors every aspect of the Aaron 2250's output. At the sign of any problem the machine instantly disables the output and displays the appropriate error code on the display.
Dimensions and Weight
Width: 31.1 cm (12.3")
Height: 15.3 cm (6.0")
Depth: 41.3 cm (16.3")
Weight: < 8.8 kg (< 19 lbs.)
Warranty
(Unit) - 2 years
Ships With:
Unit, Power Cord and User's guide.
Special order item, therefore it cannot be canceled once the order has been placed and is non-returnable after it has been received.

Share this page