Products available to Physicians Overstock Items Customer Service My Account My Shopping Cart  
July 9, 2008
MSDS Listings Subscribe to D*News Request Catalog


  Chemicals
  Cosmetic Surgery
  Cryosurgery
  Diagnostic
  Electrosurgery
  Examination
  Instruments
  Laboratory
  Lighting
  Patient Resale
  Pharmaceuticals
  Photography
  Protection
  Reference
  Sharps
  Sterilization
  Surgery
  Wound Care
  Veterinary
 
Lighting \ Outpatient II

Technical Information


General Information
The Outpatient II light uses the most recent developments in light sources and materials to produce a superior procedure light for a wide variety of surgical, examination and procedure needs. The Outpatient II light is focusable and yields a very cool beam with uniform illumination. Other features include long bulb life, large illumination field due to a unique triple low voltage halogen bulb system and double filtering optics.

Approvals
Listed by UL (Underwriters Laboratories), CSA Certified, FDA registered.

Materials
 Light Housing:  polycarbonate (Lexan) structural foam

 Yoke and arm/pivot adapters:  aluminum

 Yoke cover/arm tube:  steel

Electrical Characteristics
 Input Voltage:  115 volts AC, 60 Hz (cycles), single phase (may be wired for 230 volts AC, 50/60 Hz)

 Input Current:  1.5 amperes (115 volts) or 0.75 amperes (230 volts)

 Bulb Type:  FTY 8 degrees tungsten halogen with integral dichroic reflector, 12.0 volts, 50 watts, wired in parallel so that if one bulb burns out the others will remain on.

 Bulb Life:  2000 hours average (each bulb).

 Power Cord:  Ceiling mounts are directly wired in. Floor stand base and wall mount have SJT 18 AWG 3 wire 6' long power cords with a hospital grade plug.

 Power Switch:  Push button, rated 12A at 250 v AC, double pole single throw for On/Off

 Lamp Socket:  Dual pin; ceramic

 Current Leakage:  Less than 100 micro amperes

Optical Characteristics
Distance (inches) (ft-cd) IntensitySpot Diameter
1814,000 (FC) / 151,200 (LUX) 3 - 5 (in) / 7.62 - 12.70 (cm)
247,400 (FC) / 79,920 (LUX)5 - 7 (in) / 12.7 - 17.8 (cm)
363,600 (FC) / 38,880 (LUX)6 - 8 (in) / 15.24 - 20.32 (cm)

Color temperature: Approximately 3,600° Kelvin.

Infrared in the beam: Less than 25 milliwatts/square cm/fc (to IES standard).

Lighthead and Arm
Light head has three "pods": 8" from head axis to end of each pod, 4" (10.2 cm) lighthead thickness, 26" (66 cm) from lighthead pivot to arm attachment axis. Lighthead supplied removable and sterilizable autoclavable handle that accepts sterile covers. Sterile cover is included with each unit and replacement sets of 25 sterile packs are available (part number 0008100PK). Lighthead pivots 170 degrees on its yoke and the yoke pivots 340 degrees on the flexible arm. The flexible arm pivots 40 degrees above and below horizontal, for a total angular travel of 80 degrees. Guards around bulb opening; positioning knob.

Floorstand Base
Maximum over all dimensions: 18" (46 cm) side to side, 19" (48 cm) front to back, 4.5" (11.4 cm) to top of legs. Includes four continuous swivel non-conductive casters (two locking casters)..

Floorstand Upright
Maximum over all height installed in base: 66" (168 cm), 1.5" (3.2 cm) diameter: with lighthead pointing down, distance from floor to front face is adjustable from 44" to 72" (112 cm to 183 cm). Head and arm pivot 40 degrees between floorstand base legs. Floorstand is equipped with wire wraps.

Single Ceiling Mount
12" (30.5 cm) diameter mounting plate and cover attaches to reinforced ceiling with three fasteners, 3/8" (9.53 mm) diameter, located on an 8" (203 mm) diameter hole circle, electrical input wires routed through a 2" (50.8 mm) cutout. Contains one ceiling mount pole which allows installation in rooms with ceilings up to 9.5' high (2.89 m) based on installing the arm at 80" (2.03 m) above the floor. Contains one fixed horizontal extension arm which is 17" (431.8 mm) from pivot to pivot. The extension arm pivots 320 degrees on the ceiling mounting pole and the flexible arm pivots 320 degrees on the extension arm. Maximum reach is 43" (1.09 m) from the ceiling pole axis to the lighthead pivot

Double Ceiling Mount
Mounting plate, cover, pole and extension arm dimensions, pivot data, and reach data same as single ceiling mount. Contains two extension arms.

Wall Mount
7" (177.8 mm) high 6" (152.4 mm) wide casting attaches to a main wall structural member (stud) or reinforcement as necessary with two fasteners 3/8" (9.53 mm) diameter. Casting extends 6" (152.4 mm) away from the wall. Contains one extension arm, 17" (431.8 mm) from pivot to pivot. Extension arm pivots 180 degrees on wall mount. Flexible arm pivots approximately 320 degrees on extension arm.

Finish
All products are painted light gray as a standard finish. Custom colors are available at additional charge – call for quotation.








  Copyright © 2008
  All Rights Reserved
  Delasco




PHYSICIAN CATALOG / OVERSTOCKS / CUSTOMER SERVICE / MY ACCOUNT
SHOPPING CART / MSDS INDEX


Delasco   608 13th Ave.   Council Bluffs, IA USA 51501-6401
voice: (800) 831-6273   (712) 323-3269
fax: (800) 320-9612   (712) 323-1156
questions@delasco.com